QMI.JPG (6876 bytes)  QMI Inc.    AIRSCAN   SCANNERS   ULTRASONIC TESTING    EDDY CURRENT    REQUESTS    ADDRESSES   

 

AIRSCAN® Transducers

image004.jpg (6659 bytes)

Highly attenuative materials are readily tested using our 120kHz ceramic transducers (ceramic transducers are more robust than electrostatic transducers) ,  providing an optimum combination of  resolution and penetration.  Our 225kHz ceramic transducers offer increased resolution, while still providing robust penetrating power. The high frequency of 400kHz ceramic transducers yield the best lateral resolution, while the low frequency 50kHz transducers are used for the most attenuative materials (thick section foam core & multi-septum parts).

 

AS_Freq_Compare_2.jpg (2194359 bytes)

 

Airscan® transducers are specifically designed for use in conjunction with QMI’ s Sonda 007CX Airscan® Instrumentation, and are not compatible with conventional ultrasonic instrumentation.   QMI does not supply these transducers apart from the Sonda 007CX.

 

AS50AR APRTR.JPG (17877 bytes)
AS50ARi APERTURE SCAN

 

AS50AR BEAM.JPG (16720 bytes)
AS50ARi BEAM PROFILE

 

AS50AR D-A.JPG (20051 bytes)
AS50ARi DISTANCE/AMPLITUDE PLOT

 

AS50A WAVEFORM.JPG (35575 bytes)
AS50ARi WAVEFORM & SPECTRUM

 

AS50R CONFIG.JPG (16484 bytes)
AS50ARi CONFIGURATION

 

AS50T APRTR.JPG (17877 bytes)
AS50Ti APERTURE SCAN

 

AS50T BEAM.JPG (16693 bytes)
AS50Ti BEAM PROFILE

 

AS50T D-A.JPG (19915 bytes)
AS50Ti DISTANCE/AMPLITUDE PLOT

 

AS50A WAVEFORM.JPG (35575 bytes)
AS50Ti WAVEFORM & SPECTRUM

 

AS50T CONFIG..JPG (14786 bytes)
AS50Ti CONFIGURATION

 

 

120 FOC-AP.JPG (21728 bytes)
AS120ARi APERTURE SCAN

 

120 FOC-BEAM.JPG (21307 bytes)

AS120ARi BEAM PROFILE

 

120 FOC D-A.JPG (21227 bytes)
AS120ARi DISTANCE/AMPLITUDE PLOT

 

120 FOC-WAVEFORM.JPG (34603 bytes)
AS120AR WAVEFORM & SPECTRUM

 

AS120R CONFIG.JPG (15012 bytes)
AS120ARi CONFIGURATION

 

120 FLAT-AP.JPG (22386 bytes)
AS120Ti APERTURE SCAN

 

120 FLAT-BEAM.JPG (21653 bytes)

AS120Ti BEAM PROFILE

 

120 FLAT D-A.JPG (21224 bytes)

AS120Ti DISTANCE/AMPLITUDE PLOT

 

120 FLAT-WAVEFORM.JPG (34338 bytes)
AS120Ti WAVEFORM & SPECTRUM

 

120 FLAT-CONFIG.JPG (14176 bytes)
AS120Ti CONFIGURATION

 

 

400 FOC-AP.jpg (41846 bytes)
AS400Ri APERTURE SCAN

 

400 FOC-BEAM.jpg (61738 bytes)
AS400ARi BEAM PROFILE

 

400 FOC-DA.jpg (41033 bytes)
AS400ARi DISTANCE/AMPLITUDE PLOT

 

400 FOC-WAVEFORM.JPG (25649 bytes)

AS400ARi WAVEFORM & SPECTRUM

 

AS400R CONFIG.JPG (19324 bytes)
AS400ARi CONFIGURATION

 

400 FLAT-AP.JPG (51844 bytes)
AS400Ti APERTURE SCAN

 

400 FLAT-BEAM.JPG (42397 bytes)
AS400Ti BEAM PROFILE

 

400 FLAT D-A.jpg (40287 bytes)

AS400Ti DISTANCE/AMPLITUDE PLOT

 

400 FLAT-WAVEFORM.JPG (43806 bytes)
AS400Ti WAVEFORM & SPECTRUM

 

AS400T CONFIG.JPG (18651 bytes)
AS400Ti CONFIGURATION

 

HOME |  AIRSCANINSTRUMENTS |  SCANNERS  | ULTRASONIC TESTING  |  REQUESTS |  ADDRESSES